Part Number |
Details |
|
30 series Check Valves |
Check Valves: These items features a poppet design with and ‘O’ ring seal for positive closure. Closing of the valve occures when the manifold pressure dops 0.5 PSIG bellow the cable pressure. This part utilizes a plastic collar, is re-usable and requires no special tools.
30-3/8 – Air flow direction from 3/8 tube connection to 1/8″ Male NPT.
30M-3/8 – Air flow direct from 1/8″ Male NPT to 3/8 Tube connection. Replaces AMPFIT part # 556456-1.
|
|
62P-6 |
This part is used in the Air Pipe system specifically for connecting the 3/8″ tubing. This part utilizes a plastic collar, is re-usable and requires no special tools. Replaces AMPFIT part # 561302-1.
|
|
3090-3/8 |
Check-Valve with air flow direction from 3/8 tube connection to 1/8″ Male NPT with 90 elbow fitting. This part utilizes a plastic collar, is re-usable and requires no special tools. Replaces AMPFIT part # 556458-1.
|
|
68P-6-4 |
This part is used in the Air Pipe system for connecting the 3/8″ tubing into an existing fitting with female 1/4″ NPT . This part utilizes a plastic collar, is re-usable and requires no special tools. Replaces AMPFIT part # 561312-1.
Note: 68P-6-2 is similar with the exception being the 1/8″ Male NPT. Replaces AMPFIT part # 561310-1.
|
|
164P-6 |
This part is used in the Air Pipe system specifically for connecting (3) 3/8″ tubing ends or running a branch off of an existing 3/8″ tubing run. This part utilizes a plastic collar, is re-usable and requires no special tools. Replaces AMPFIT part # 561304-1.
|
|
8779 |
Check Valve to be used as a protective device installed between the CA3131 Gas Feeder Pipe and the manifold assembly, the valve will close when pressure drops 0.2 PSIG below the manifold pressure. The check valve features high flow capacity, minimal pressure drop and “bubble-tight” shutoff. A 1/8″ NPT Hex Nipple is included
|
|
169P-6-2 |
This part is used in the Air Pipe system specifically for connecting 3/8″ tubing ends into the air system. This part utilizes a plastic collar, is re-usable and requires no special tools. Replaces AMPFIT part # 561314-1.
|
|
68P-6END |
This part is used in the Air Pipe system specifically for capping off a 3/8″ tubing end. This part utilizes a plastic collar, is re-usable and requires no special tools. Replaces AMPFIT part # 561308-1.
|
|
170-68P-6-6 |
This Elbow fitting is used to connect to 3/8″ poly tube ends in the CA3131 air pipe system. Sold in packages of 10. This part utilizes a plastic collar, is re-usable and requires no special tools. Replaces AMPFIT part # 561318-1.
|
|
75481 |
The C Flange, used in pressure testing, is tin dipped so that it can be soldered to the lead sheath cable. This flange is used in conjunction with a test valve stem (see our 6914F under the valves and accessories page) or the 75482 plug shown here. Purchased in packs of 25 pcs.
|
|
75482 |
The C Flange plug is used in conjuction with the 75481 shown here
|
|
470-3/8 |
This shut-off assembly is designed for quick installation on 3/8″ tubing in the manhole repair or elsewhere in the air pipe system. This shutoff valve utilizes plastic collars, is re-usable and requires no special tools. Replaces AMPFIT part # 561306-1.
|
|
8336P-F |
Used in the Air Pipe Systems (CA3131), this fitting provides a F test valve as a terminating point for the air pipe. A bonding kit is also included. This part utilizes a plastic collar, is re-usable and requires no special tools. Replaces AMPFIT part # 561683-1.
|
|
8336PCPL |
Used in the Air Pipe Systems (CA3131), this fitting provides a connection between two pieces of air pipe. A bonding kit is also included. This part utilizes a plastic collar, is re-usable and requires no special tools. Can replace AMPFIT part # 332843.
|
|
8336P-PIE |
The Pulling Eye used for pulling the the Air Pipe (CA3131). The Pulling Eye has a 5/16″ diameter pulling hole, utilizes a plastic collar, is re-usable and requires no special tools. Replaces AMPFIT part # 561274-1.
|
|
8336PANEL |
Used in the Air Pipe Systems (CA3131), this fitting facilitates a connection point for the air pipe to the Panel. A high density poly fitting creates a non-conductive connection. This part utilizes a plastic collar, is re-usable and requires no special tools. This part replaces AMPFIT part # 561411-1.
|
|
470PCLVB |
This shut-off assembly is designed for quick installation in the manhole to provide a readily accessible test or isolation point in the air pipe for analysis, leak location, repair or air pipe system rearrangement. Equipped with an F test valve on each side of the shut off and a bonding kit. This part utilizes a plastic collar, is re-usable and requires no special tools. Replaces AMPFIT part # 561604-1.
|
|
8336P-3/8 |
Used in the Air Pipe Systems (CA3131), this fitting provides a 3/8″ tube fitting for transitioning from the CA-3131 air pipe to the 3/8″ tubing. A bonding kit is also included. This part utilizes a plastic collar, is re-usable and requires no special tools. Replaces AMPFIT part # 561720-1.
|
|
8336PCEB |
Used in the Air Pipe Systems (CA3131), this fitting provides a terminating point for the air pipe along with a 1/8th NPT port for a pressure testing valve or other connections. A bonding kit is also included. This part utilizes a plastic collar, is re-usable and requires no special tools. Replaces AMPFIT part # 332841.
|
|
8336P-TEE |
Used in the Air Pipe Systems (CA3131), this fitting provides a “T” connection between three pieces of 1/2″ air pipe. A 1/8th NPT port for a pressure testing valve, plug or other connections. A bonding kit is also included. This part utilizes a plastic collar, is re-usable and requires no special tools. This replaces AMPFIT part # 561515-1.
|
|
8336PCENB |
Used in the Air Pipe Systems (CA3131), this fitting facilitates a connection point for the air pipe to a 1/4″ female pipe thread. A bonding kit is also included. This part utilizes a plastic collar, is re-usable and requires no special tools. This part replaces AMPFIT part # 332842.
|
|
8336PCLB |
Used in the Air Pipe Systems (CA3131), this fitting provides a connection between two pieces of air pipe. A 1/8th NPT port for a pressure testing valve or other connections. A bonding kit is also included. This part utilizes a plastic collar, is re-usable and requires no special tools. Can replace AMPFIT part # 332823.
|
|
8336PCTB |
Used in the Air Pipe Systems (CA3131), this fitting provides a connection between two pieces of air pipe. A 1/4th NPT port for a pressure testing valve or other connections. A bonding kit is also included. This part utilizes a plastic collar, is re-usable and requires no special tools. Can replace AMPFIT part 332824
|
|
8622-100-1F |
The Hi-Valve single valve can be located on a pole or at the neck of a manhole. This block has 1 “F” pressure testing valve and 1 “B” connector attached.
|
|
8622-100-2F |
The Hi-Valve double valve can be located on a pole or at the neck of a manhole. This block has 2 “F” pressure testing valves and 2 “B” connectors attached.
|
|
8622-5 |
This Hi-Valve Connecting Block features a convenient means for terminating the plastic tubing connect to each underground cable. This block has 5 “F” Pressure testing valves and 5 “B” connectors.
|
|
8664 |
The 8664 is used for constructing a by-pass across a pressure plug. It comes equiped with (2) 3/8″ tube connections and (2) F test valve points. The diaphram in the housing can be opened and closed with an flat-head screw driver.
|
|
8669 |
This F Pressure flange and 1/8 NPT fitting is ideally suited for use at pressure reading points, bypasses or air inlets at any 3/4 in. (19 mm) dia. or larger cable. 2 hose clamps are required for attachment.
|
|
8669LF |
This combination F flange kit and 1/8 NPT fitting is ideally suited for creating pneumatic connections, bypasses or air inlets at any 1″ to 2″ dia. or larger cable. 2 hose clamps required for attachment.
|
|
8669LG |
This combination G flange kit and 1/8 NPT fitting is ideally suited for creating pneumatic connections, bypasses or air inlets at any 2″ to 3″ dia. or larger cable. 2 hose clamps required for attachment.
|
|
8778-2 |
Plated Brass manifolds equipped with individual shut off valves, pressure testing valves and tubing connections for 2 cables with an additional pretture testing valve for reading manifold pressure.
|
|
8778-3 |
Plated Brass manifolds equipped with individual shut off valves, pressure testing valves and tubing connections for 3 cables with an additional pretture testing valve for reading manifold pressure.
|
|
8778-5 |
Plated Brass manifolds equipped with individual shut off valves, pressure testing valves and tubing connections for 5 cables with an additional pretture testing valve for reading manifold pressure. The inflow consists of a pre-fitted 1/8″ elbow which can be mated with the 68P-6-2 polyfitting for connection to the incoming 3/8″ tubing. As with the other CA-3131 air pipe fittings, it utilizes a plastic collar, is re-useable and requires no special tools.
|
|
8778-5FT |
Plated Brass manifold that comes with pre-equipped with check valves at the (5) out-flowing 3/8″ fittings. This manifold, like the others, is equipped with individual shut off valves, pressure testing valves and tubing connections for 5 cables with an additional pretture testing valve for reading manifold pressure. The inflow consists of a pre-fitted 1/8″ elbow which can be mated with the 68P-6-2 polyfitting for connection to the incoming 3/8″ tubing. As with the other CA-3131 air pipe fittings, it utilizes a plastic collar and is re-useable.
|